Home / Templates / Wine Cellar Cooling Unit Shortlist Worksheet
Free worksheet

Wine Cellar Cooling Unit Shortlist Worksheet

A side-by-side worksheet for comparing up to three cooling units against your cellar's calculated load, heat rejection options, noise, running cost, and service support.

Download the worksheet (.csv)

Reviewed for 2026, updated September 8, 2026.

Cooling units are sold on cubic footage, but a cellar is cooled on heat load, and the two only agree when the room is well insulated, mostly opaque, and sitting in a mild space. This worksheet asks you to compare shortlisted units on the figures that actually decide whether the room holds temperature in August: rated capacity against your design load, the temperature difference the unit is rated for, where the heat goes, and how much the compressor draws when it runs. Fill it in from spec sheets and installer quotes rather than product pages.

Start by running the Wine Cellar Cooling Load Calculator at /tools/cellar-cooling-load/ so you have a design load and suggested rating to compare against, then use the running watts you record here in the Wine Cellar Cost of Ownership Calculator at /tools/cellar-ownership-cost/. The cooling article at /blog/passive-vs-active-cooling/ explains the system types in the first row. The cells below are placeholders for your own figures; we deliberately do not prefill them with numbers.

What to compareUnit AUnit BUnit CWhy it matters
System type (through-wall, ducted, or split)Your entryYour entryYour entryDecides where the heat and noise end up and how invasive the installation is
Rated capacity in BTU/hrYour figureYour figureYour figureShould clear the suggested rating from the cooling load calculator with margin
Maximum temperature difference the unit is rated forYour figureYour figureYour figureA unit rated for a small difference will not hold a cellar beside a warm garage
Running watts from the spec sheetYour figureYour figureYour figureDrives the electricity line in the ownership cost calculator
Humidity handling (adds, holds, or only cools)Your entryYour entryYour entrySome units dry the air as they cool and need a separate humidifier
Heat rejection space or condenser locationYour entryYour entryYour entryThe heat has to go somewhere that can absorb it without warming the cellar wall
Noise at the cellar side and at the condenser sideYour entryYour entryYour entryThrough-wall units put the compressor within earshot of the adjacent room
Condensate drain or evaporation methodYour entryYour entryYour entryA drain line changes where the unit can sit and who installs it
Installed price from a written quoteYour quoteYour quoteYour quoteCompare installed figures only; the unit price alone hides ducting and electrical work
Warranty length and nearest service providerYour entryYour entryYour entryA long warranty is worth less if nobody within driving distance services the brand
Expected service life and replacement reserve per yearYour figureYour figureYour figureSplit and ducted systems often justify a smaller annual reserve than through-wall units